Cookie Img
Send Inquiry Send SMS
Home » Products » Emergency And Portable Ventilator » Emergency And Portable Ventilator

Emergency And Portable Ventilator

Emergency And Portable Ventilator
Emergency And Portable Ventilator
Product Code : 01
Product Description

Emergency And Portable Ventilator

We have marked a distinct position for ourselves in the market by manufacturing and exporting a superior range of Emergency And Portable Ventilator. These ventilators are designed to mechanically move breathable air into and out of the lungs in order to provide instant relief to the patient. We employ advance machines and quality approved materials to manufacture Emergency And Portable Ventilator, in accordance with industry set norms and standards. We lay prime emphasis on the packaging of these ventilators for safe delivery at clients™ premises.

Features:

  • Durable deign
  • Advanced service life
  • Easy to us

Technical Specification

Specification
Modes of ventilation
icon2 Assist/Control (A/C)  
icon2 Synchronized Intermittent Mandatory Ventilation (SIMV)  
icon2 Manual ventilation (Manual)  
icon2 Combined: VCV + SIGH  
parameter
icon2 Tidal volume: 0~1500ml
icon2 Respiratory rate: 4~99bpm(A/C mode)
icon2   4~40bpm(SIMV mode)
icon2 IE ratio: 2:1 ~ 1:4
icon2 FiO2: 48% ~ 100%
icon2 Pressure trigger sensitivity: -2~0kPa (above PEEP)
icon2 PEEP (option): 0.5 ~ 2kpa
Monitoring
icon2 Pressure values: Ppeak
icon2 Volume/flow values: V1, MV
icon2 Time values: Ftotal
icon2 Real time curves: Pressure-Time
Monitoring
icon2 Paw high, Paw low, Apnea, AC power failure, battery low, O2 deficiency
Paw high, Paw low, Apnea, AC power failure, battery low, O2 deficiency
icon2 Screen: LCD
icon2 Gas supply: O2, 0.28~0.6MPa
icon2 Power supply: AC110~240V, 50Hz/60Hz, <65VA
icon2 Maximum security pressure: <6kPa
icon2 Compliance: <4mL/100Pa
icon2 Noise: <65dB(A)
icon2 Dimension(HxWxD): 175x170x300mm
icon2 Weight: 3.5Kg
Alarm
icon2 Temperature: 0 c~40 c (Operation)
icon2   0 c~40 c (Storage)
icon2 Relative humidity: <85%, non-condensing (Operation)
icon2   <85%, non-condensing (Storage)
icon2 Atmospheric pressure: 70~110kPa(Operation)
icon2   70~110kPa(Storage)

GENUINE MEDICA PVT. LTD.

Contact Us

( *represents compulsory fields )

Tips on getting accurate quotes. Please include product name, order quantity, usage, special requests if any in your inquiry.



GENUINE MEDICA PVT. LTD.
D-10/3, First Floor, Okhla Industrial Area, Phase-II, New Delhi - 110020, India
Phone :+917533005935
Fax :91-11-40513400
Mr. Manish Kumar Shrivastav (Director)
Mobile :+917533005935
Mr. Ashwani Arora (Director)
Mobile :+917533005935
Send Inquiry Send SMS